Showing all 3 results
Flood-Control
4.900,00 ден
Flooding and temperature sensor
Universal flooding and temperature sensor.
Flood-Control can be placed on a floor or
wall, using the inputs to install the probe
contacts.
The LED indicator and acoustic alarm alert
the user in the event of flooding and the tilt
sensor warns if the device is moved or tipped.
If a water leak is detected, the system (if it
includes solenoid valves) will also shut off the
water, minimising the damage caused by the
malfunction.
The LED can also be used during field testing of
the Z-Wave network.
The device can be powered by battery or cable
(12/24 VDC).
Flood-Control floats on the surface of the water,
preventing it from being submerged.Main features:
• Compatible with Z-Wave and Z-Wave Plus
control systems.
• Unique design.
• Flooding detection and acoustic warning.
• Battery or VDC powered.
• Communicates with the Z-Wave network or
an alarm system via cable.
• With wireless update capability.
TECHNICAL SPECIFICATIONS
Code Description Pcs./pack Certificates
FLOOD-CONTROL Flooding and temperature sensor 1
Code FLOOD-CONTROL
Power supply 12 - 24 VDC
Battery type CR123A (included)
Maximum voltage at output terminals 24 VDC / 20 VAC
Complies with European standards RED 2014/53/EU - RoHS 2011/65/EU
Operating temperature (°C Min/Max) 0 - 40
Temperature measurement range (°C Min/Max) -20 - 100
Precise temperature measurement. (°C) 0.5 (within 0 - 40 range)
Radio protocol Z-Wave (500 series)
Radio frequency (MHz) 868.4, 869.85 (EU) / 908.4, 916.0 MHz (US) / 921.4, 919.8 MHz
(ANZ) 869.0 MHz (RU)
Radio range (m) up to 40m (depending on building structure)
Dimensions (mm) 72 Ø x 28 h
Motion-Control
4.150,00 ден
Motion, light and temperature sensor
Motion-Control multifunctional wireless
sensor can detect motion, temperature and
light intensity. It can also detect changes in
position and attempts to tamper with the outer
housing.
Motion-Control is battery powered and updated
via radio. Sensitivity can be adapted to the
user’s needs.
The built-in LED provides information on
recorded movements and temperature changes.
The available functions include a Z-Wave field
tester.
It can be installed quickly, non-invasively and
on any surface. The universal mount enables
the sensor to be located anywhere (including on
walls and ceilings).
Main features:
• Compatible with Z-Wave and Z-Wave Plus
control systems.
• It detects even the slightest movement and
change in temperature.
• It is the only one of its kind with an earthquake
detection function.
• Battery-powered.
• Wireless communication via the Z-Wave
protocol.
• With wireless update capability.
• Supports Security Mode (Z-Wave network
security system) with AES-128 encryption.
TECHNICAL SPECIFICATIONS
Code Description Pcs./pack Certificates
MOTION-CONTROL Motion, light and temperature sensor 1
Code MOTION-CONTROL
Battery type CR123A battery, 3.0 VDC (battery included)
Recommended installation height (m) >2
Operating temperature (°C Min/Max) 0 - 40
Temperature measurement range (°C Min/Max) -20 - 100
Precise temperature measurement. (°C) 0.5 (within 0 - 40 range)
Light intensity measurement threshold (LUX) 0 - 32000
Radio protocol Z-Wave (500 series)
Radio frequency (MHz) 868.4, 869.85 (EU) / 908.4, 916.0 (US) / 921.4, 919.8 (ANZ) / 869.0 (RU)
Radio range (m) up to 40m (depending on building structure)
Compliant with European directives RED 2014/53/EU - RoHS 2011/65/EU
Dimensions (mm) 56 x 56 x 58.5 h Smoke-Control
5.300,00 ден
Smoke and temperature sensor.
Lightweight device with photoelectric
and temperature sensors to detect the
presence of smoke or incipient fire as early
as possible.
Battery powered for possible ceiling installation.
Smoke detection is indicated by an acoustic
signal, flashing LED and sending of the relevant
information to the Z-Wave network.
If the smoke sensor detects a hazardous
situation, it can initiate the alarm scenario. In this
case, the user will immediately receive an alert
on their phone, wherever they are.
The device has an integrated temperature
sensor able to activate the alarm in the
presence of high temperatures. The occupants
of the house will be alerted, even if the fire
occurs without smoke emission.
One feature making the equipment unique is the
ability to analyse data from past events, so that
similar dangers can be avoided in the future.
Main features:
• Compatible with Z-Wave and Z-Wave Plus
control systems.
• 3 levels of sensitivity, in accordance with EN
14604:2005.
• Built-in housing opening detector.
• A safety mechanism prevents the housing
from being closed without a battery installed.
• An alarm is signalled by a loud sound, LED
indicator and message sent to the Z-Wave
network.
• An additional feature signals a rise in
temperature above a preset threshold.
• Diagnostic efficiency test every 10 seconds to
prevent possible malfunctions.
• The self-test function can be implemented
manually
• All temperature and smoke readings are
recorded in an internal memory.
TECHNICAL SPECIFICATIONS
Code Description Pcs./pack Certificates
SMOKE-CONTROL Smoke and temperature sensor 1
Code SMOKE-CONTROL
Battery type CR123A 3.0V DC (included)
Operating temperature (°C Min/Max) 0 - 55
Operating humidity 0% - 93%
Temperature measurement range (°C Min/Max) -20 - 100
Precise temperature measurement. (°C) 0.5 C (within 0C - 55C range)
Smoke sensitivity level 1: 1.20 +/- 0.5% obs/ft, level 2: 1.80 +/- 0.5% obs/ft,
level 3: 2.80 +/- 0.5% obs/ft
Sound intensity level 85dB / 3m
Radio protocol Z-Wave (500 series)
Radio frequency (MHz) 868.4, 869.85 (EU) / 908.4, 916.0 (US) / 921.4, 919.8 (ANZ) / 869.0 (RU)
Complies with LVD 2006/95/EC - EMC 2004/108/EC - R&TTE 1999/5/EC -
RoHS 2011/65/EU - EN 14604:2005
Radio range (m) up to 40m (depending on building structure)
Dimensions (mm) 65 Ø x 28 h